RF-YG-08
RF-YG-08 Permanent Crown Resin 25% in shade A2
Permanent Crown Series

Permanent Crown Resin 25%

Color:
A2
Shore D: 94D

Application: Dental model
Printing: LCD / DLP
Highlights:
25% Formulation 120 MPa Tensile 140 MPa Flexural 90°C HDT

Key Features

The current TDS identifies RF-YG-08 25% as an A2 resin processed by LCD or DLP. It reports high strength, good hardness, high precision and high-temperature resistance, with 120 MPa tensile strength, 140 MPa flexural strength and a 90°C HDT at 0.45 MPa. Its application field states “Dental model,” while the safety section says the resin is not approved for medical application on the human body.

High Strength
Good Hardness
High Precision
High-Temp Resistant
120 MPa Tensile
90°C HDT

Use-status notice

Before any clinical or patient-contact use, confirm the current intended use, regulatory status and applicability with RayForm and the responsible local professional.

Basic Performance

Properties Unit Standard Result
Density g/cm³ ASTM D792 1.30–1.40
Viscosity mPa·s ASTM D445 4500
Hardness Shore D ASTM D2240 94D
Tensile Strength MPa ASTM D638 120
Elongation at Break % ASTM D638 6
Flexural Strength MPa ASTM D790 140
Flexural Modulus MPa ASTM D790 2500
HDT @ 0.45 MPa °C ASTM D648 90

Printing Parameters

The current TDS lists the following six representative machine parameters as starting references.

Printer Exposure (s) Base Exp. (s) Base Layers Lift Height (mm) Lift Speed (mm/min) Retract Speed (mm/min)
Phrozen Sonic Mini 8K S 5.5 25 3 4+4 60+120 180+60
Creality Halot-MAGE Pro 1.8 10 3 8+2 60+180 180+60
Elegoo Saturn 4 Ultra 3.3 20 3 Default standard parameters of the device
Anycubic Mono 4 Ultra 4.3 25 3 4+4 90+120 240+90
Elegoo Saturn 3 Ultra 4.1 25 3 4+4 60+180 180+90
Anycubic M7 Pro 3 20 3 4+4 60+120 180+60

Post-Processing & Storage

  • 1

    Wash – Clean the model with isopropyl alcohol in an ultrasonic cleaner. Avoid high-frequency shock or forceful brushing to protect surface details.

  • 2

    Dry – Thoroughly blow the model dry with a hair dryer or similar tool.

  • 3

    Remove Supports – Remove supports before post-curing. Removing supports after post-cure may damage the contact surface at support points.

  • 4

    Optional Post-Cure – For occasions where certain toughness is required, UV cure for 5 minutes. Store printed parts in a cool, dry place.

Storage

Store below 25°C in a cool place away from direct sunlight. Keep away from visible light to prevent resin polymerization and gelation.

Safety

Eyes: Flush with clean water for at least 20 minutes and seek medical attention immediately. Skin: Remove contaminated clothing and wash thoroughly with soap and water. Not approved for food, drink, or medical application on the human body. See MSDS for details.

Machine Compatibility

RF-YG-08 25% is processed by LCD and DLP. The current TDS provides reference parameters for these representative printers.

Phrozen Sonic Mini 8K S Creality Halot-MAGE Pro Elegoo Saturn 4 Ultra Anycubic Mono 4 Ultra Elegoo Saturn 3 Ultra Anycubic M7 Pro

Use the TDS values as starting points and validate them for your equipment and workflow.

TDS-Described Dental Workflow

The product name and TDS narrative describe permanent-crown and restorative workflows, but the same document lists the application as “Dental model” and states that the resin is not approved for medical application on the human body. Confirm current intended use and applicable documentation before patient contact.

RF-YG-08 Permanent Crown Resin 25% printed example
RF-YG-08 Permanent Crown Resin 25% dental workflow example

Frequently Asked Questions

  • Q
    What are the core TDS values for RF-YG-08 25%?
    Density 1.30–1.40 g/cm³, viscosity 4500 mPa·s, Shore D 94, tensile strength 120 MPa, elongation 6%, flexural strength 140 MPa, flexural modulus 2500 MPa and HDT 90°C at 0.45 MPa.
  • Q
    Which printing technologies and machines are listed?
    The TDS specifies LCD/DLP and provides starting parameters for Phrozen Sonic Mini 8K S, Creality Halot-MAGE Pro, Elegoo Saturn 4 Ultra and Saturn 3 Ultra, Anycubic Mono 4 Ultra and M7 Pro.
  • Q
    How should parts be post-processed?
    Clean with IPA in an ultrasonic cleaner without high-frequency shock or forceful brushing, dry fully, remove supports before post-curing, and use 5 minutes of UV curing when toughness is required.
  • Q
    Does this page establish clinical approval?
    No. The current TDS lists “Dental model” as the application and states that the resin is not approved for medical application on the human body. Confirm current product and market documentation before patient contact.

Evaluating RF-YG-08 25% for your workflow?

Request current documentation and starting parameters to validate printing and post-processing on your equipment.